Site transformer

STM3100C : Site transformer

10kVA Three phase site transformer
400V to 6 x 110V (16 and 32 amp outlets)





Price for 1+: £464.75 each.
Price for 5+: £442.00 each.
Weight: 80.00 kg.
VA: 10,000 VA.
  • Tool rating: 10,000VA
  • Continuous rating: 10,000VA
  • Input: 1 x 400V (16amp triple pole supply)
  • The STM3100C is fitted with Triple pole 16amp type D MCB
  • Outlets: 4 x 110V 16Amp BS4343 sockets + 2 x 110V 32A BS4343 sockets
  • Constructed with a robust heavy duty site case and housed under a weatherproof cover.
  • Dimensions:
  • Height: 59cm (including top handles 64cm)
  • Width: 51cm (including handles 57cm)
  • Depth: 44cm
  • British built
  • Delivery within 48 hours
Rating: 10kVA Continuous
Input Voltage Voltage & Frequency 400volts @ 16amps 50/60HZ
Output Voltage: 110volts CTE @ 53amps
Ambient Temperture: 30 deg C
No of Phases: Three
Earthing: Earth Screen Between Primary & Secondary Winding
Thermal Insulation: Class E Max 120 deg C Temperture Rise 75 deg C
Socket Outlets: 2x32amp 4x16amp 110volt BS4343 Panel mounting Sockets
Output Protection: 2x32amp & 2x20amp 2 Pole Type C MBC
Input Protection: 1x16amp 3 Pole Type D MCB
Tripping Characteristics: European Standards EN60898 (-25 deg C - +55 deg C)
Enclosure: Sheet Steel Ventilated Drip Proof IP40 + Weatherproof cover over MCB
Dimensions & Weight: Width 510 Height 590/650 to top of Handles Depth 450mm Weight 86kilos
Climate Class: Outdoor Use
Cooling: Method ANAN Medium: Natural Air
Quantity:       This product is in your basket
BASIC SAFETY
Before using this equipment and to avoid personal injury, carefully read and understand these instructions. If there is anything you do not understand. DO NOT use this equipment, seek advise.
Make sur you are aware of all safety requirements and that this equipment is suitable for the task you wish to undertake.
The work area must be cordoned off from the general public and bystanders.
Persons who are under the influence of alcohol or drugs must not operate this equipment.
You must perform a risk assessment before using this equipment to ensure your safety and the safety of others.
Wear the correct personal protective equipment for the task ahead.
Do not wear loose jewellery or clothing that may get in the way of your work.
Inform everyone in the area of what you are doing.
This equipment may weigh in excess of 25 kilos, if so, do not lift it by yourself, GET HELP.
Ensure adequate ventilation when using this equipment. Do not operate the unit close to flammable or explosive materials.
Do not lift or remove the unit by its power supply cable.
Always switch OFF the unit when cleaning, making adjustments or when left unattended.
Transport, store and operate this equipment in an upright position.
Carefully inspect the equipment before use, if there is any doubt about its condition, DON'T USE IT. Check specifically for damage to casing, power sockets and leads.

HEAT DAMAGE RISK
Never place a portable transformer on any surface, which may be damaged by heat. Regardless of size or type, all portable transformers work at high temperatures. These temperatures are sufficient to melt linoleum and synthetic carpet. Severe damage will also be caused to wood and similar materials.
Heat produced by the transformer is increased if the transformer is operated at its intermittent (max) rating.
Only place the transformer on a surface you know, is heat resistant.

ELECTRICAL SAFETY
Portable transformers require a standard 230v 13amp power supply.
If the equipment fails, or if any part becomes damaged, return it. DO NOT repair it yourself.
Do not plug the transformer into an extension lead, only use extension leads from the transformer.
Fully unwind and loosely coil all extension leads. Position them away from the equipment where they will be protected from water, sharp objects and where they will not pose a trip hazard.
Keep the equipment dry; protect this equipment from damp or wet conditions.
For additional safety always use an RCD between the transformer and the item being powered.
Switch the power OFF before plugging into the supply.

*WARRANTY
All our transformers are maunfactured using the finest materials and are subject to stringent testing before leaving the factory. If there is a manufacturing fault in a site transformer bought from us, we will refund you the purchace price. You simply need to return the transformer to us (see contact page for address) with the original receipt and after we assess the fault, assuming it is a manufactuing fault, we will credit you the cost of the item.

Transformer Manufacturer
Airlink Transformers - The UK Transformer Manufacturer
Home
Transformer Products
Portable Tool Transformer
American 120V transformer
Toroidal transformers
Lighting transformers
Electronic Transformers
Step up / step down
Japanese 100V transformer
Industrial transformers
Custom built transformers
UK to US transformers
Waterproof transformers
Balanced power supplies
Toroidal cores
AC DC Power adaptors
American Motor Home
Security equipment power
View Basket
Check Out
Common Questions
Contact Airlink
About Airlink
Useful Links
Site Map
Terms & Conditions
ISO 9001:2000
 
 
 
Transformer Manufacturer